Home › Furnace Blink Codes › Furnace Blinking 6 Times

Furnace Blinking 6 Times: What It Means and How to Fix It

Furnace guide · Decoded from manufacturer documentation · Safe homeowner checks only, gas and wiring work is professional only

Six blinks is the furnace blink pattern most likely to be misread, because it does not have one meaning. On Goodman furnaces it means the flame rollout switch is open, on many York furnaces it means the modulating gas valve has failed, and on American Standard furnaces it means the electrical polarity is reversed. The homeowner job here is therefore chart first and hands off: read the chart inside your blower door, work the external checks in this guide, run one power reset, and hand the exact pattern and brand meaning to a technician, without opening the burner compartment, touching gas parts, or testing mains wiring.

Why this happens

A furnace control board watches a chain of safety devices before and during every heat cycle, and it reports a break in that chain as a blink count. The trouble with six blinks is that different manufacturers assign the same count to different links in the chain, because there is no universal blink standard across brands. On Goodman models the board lists six flashes as an open rollout switch, a small heat sensitive safety device above the burners that opens when flames or excess heat escape the burner box, caused by blocked venting, a weak inducer, a blocked or cracked heat exchanger, or a switch weakened with age. On York models six red blinks point instead at the modulating gas valve, the part that meters gas to the burners, and a valve that cannot modulate or seal correctly will lock the furnace out rather than risk an uncontrolled flame. On American Standard models six blinks point at reversed polarity, meaning the line and neutral conductors of the furnace supply are swapped, which some control boards detect and refuse to run on. Rheem reports vary further, with some six blink cases tracing to an inducer that never starts, a board or wiring fault rather than a burner fault. Two neighbours with the same blink count can therefore have entirely different faults, which is why the door chart, not a general table, decides the diagnosis.

Finding the cause

The door chart decides what 6 blinks means on your furnace

This is the first check and the one that makes the rest of the guide usable. Count the flashes carefully, note the pause between groups, and read the chart printed inside the blower door or on the back of the top door. Goodman charts list six flashes as an open rollout switch. York charts and York guidance describe six red blinks as a modulating gas valve failure. American Standard guidance describes six blinks as a polarity fault. If your chart says something else, your chart wins, and the checks below still apply in the same order, because filter, vent, inducer sound, and one reset are relevant to every version of the fault. If the chart is missing, faded, or unreadable, treat the meaning as unknown and call a professional rather than guessing from a brand table, since a rollout fault and a polarity fault are repaired by different trades and neither is a homeowner job. Write down the exact wording from your chart before calling anyone, because a technician who hears the brand meaning on the first call arrives with the right parts and the right tests.

A blocked vent termination or a dirty filter is pushing the furnace toward a rollout trip

On the Goodman rollout version of six blinks, the exhaust path is the first physical check, because a restriction there produces exactly the pressure that makes flames roll out of the burner box. Go outside and find where your furnace vents: a plastic pipe termination on a side wall on a high efficiency furnace, or a metal flue into a chimney on an older one. Look for snow piled against the pipes, ice at the openings, leaves, a nest, or a screen clogged with debris, and check the intake pipe too if your furnace has one, because a starved intake disturbs the burn just as a blocked exhaust does. Clear anything you can reach safely from the ground, and check the filter as well, holding it up to a light and replacing it if light barely passes, because a starved furnace runs hot at the burners. This check matters because it is one of the few rollout causes a homeowner can genuinely fix: if the code clears after the termination is cleared and stays clear through a full heat cycle, the blockage was the story. If the termination was already clear, or the code returns, the restriction is inside the furnace or the flue run, and that is professional territory. Do not put anything into the flue, and never run the furnace with the vent knowingly blocked to keep the house warm.

Scorch signs near the burners confirm a real rollout on the Goodman version

A rollout event often leaves evidence, and reading that evidence from outside the furnace tells you how urgent the Goodman version of this code is. With the furnace off, look at the burner area through the sight glass if your model has one, and look at the outside of the cabinet around the burner access panel. Warning signs are blackened or blistered paint above the burner openings, soot streaks climbing the front of the heat exchanger area, wire insulation near the burners that looks melted, softened, or discolored, and a sharp burnt smell around the furnace. Any one of these means flame genuinely escaped the burner box, and the furnace should stay off until a technician finds out why, because one possible cause is a cracked heat exchanger, which is a carbon monoxide risk. Do not open the burner compartment to look closer: the observation is for triage, not diagnosis, and opening that compartment is professional work. Write down exactly what you saw and where, because scorch location helps a technician judge whether the cause is venting, the inducer, or the heat exchanger. If you find no scorch signs at all and the vent termination was blocked, a nuisance trip from the blockage alone is plausible, which the reset test below will help settle.

The inducer never starting separates a power or board fault from a burner fault

The inducer fan starts before ignition on every heat cycle, and its behaviour during a call for heat is the most useful sound check in this guide. Stand near the furnace during a call for heat, with all access panels closed, and listen to the sequence. You should hear the inducer start first and run steadily, then ignition, then the main blower. An inducer that never starts at all, while the thermostat is calling for heat and the furnace power switch is on, points away from the burners and toward power, wiring, or the control board, which matches the Rheem pattern where six blinks arrive with an inducer that never receives power. An inducer that starts and runs steadily but is followed by a lockout points back toward the rollout, gas valve, or polarity versions of the fault, depending on your door chart. This check is listen only, from outside the furnace. Do not open the compartment, touch the inducer, or test its wiring: it sits among hot surfaces, gas parts, and live electrical components. Note what you heard and at what point in the sequence the furnace locked out, because that timing separates an inducer power problem from a burner problem.

Recent electrical work points toward the polarity version on American Standard models

Reversed polarity does not develop on its own in a furnace that has run correctly for years, so its history check is different from the others. Ask whether any electrical work has happened recently: a new furnace installation, a replaced control board, a moved outlet or disconnect, rewiring after a renovation, or work on the panel that feeds the furnace. A polarity fault that appears right after such work is strong circumstantial evidence for the American Standard meaning, and it also tells you which trade to call, an electrician or the installing HVAC company, rather than a burner technician. There is no homeowner test for polarity on a hardwired furnace: confirming it means testing mains conductors inside the furnace wiring compartment, which is professional work with live voltage. Do not swap wires, do not open the junction box, and do not assume the fault is polarity just because it is on the list. If no electrical work has happened and your door chart still says polarity, the fault may be a failing board misreading its supply, which is again a professional diagnosis. Report the work history exactly as it happened, including dates, because it saves a technician a return visit.

A gas valve fault on the York version shows as ignition that never settles

On the York gas valve version, the pattern to listen for is a furnace that tries to light and never settles into a steady flame. You may hear the inducer start normally, then ignition attempts that fail, or a flame that lights for a few seconds and drops out, followed by lockout and six blinks. That pattern is consistent with a modulating gas valve that cannot meter gas correctly, but it is not proof of it, because a contaminated flame sensor, a weak igniter, or a control board fault can produce a similar failed ignition sequence. The distinction matters only to the technician, who will test the valve, the sensor, and the board in turn, and it is exactly why this guide stops at observation. Do not touch the gas valve, do not adjust any gas pressure screw, and do not repeatedly cycle the furnace to see if it eventually catches, because repeated failed ignition attempts with a faulty valve are not a safe experiment. One reset test after the external checks is the homeowner limit. If the York pattern repeats after that single reset, the furnace stays off and the call goes to a professional, with the ignition pattern described exactly as you heard it.

What you findWhat it meansWhat to do next
Door chart says open rollout switch (Goodman) and the vent termination was blockedExhaust back pressure was rolling the flames outKeep the termination clear and check it after storms and snow, then run one reset test
Scorch marks, soot streaks, or melted wire insulation near the burnersA real rollout event has happened, possibly repeatedlyLeave the furnace off and call a professional, report exactly what you saw
Inducer never starts during a call for heat, with power onA power, wiring, or control board fault is likely, not a burner faultNote the silence and the lockout timing, and call a professional
6 blinks appeared right after electrical work, chart says polarityReversed polarity from the recent work is a strong candidateCall the installing company or an electrician, do not open any wiring compartment
Ignition tries and fails, or flame lights and drops out, chart says gas valveA gas valve, flame sensor, or board fault in the ignition chainStop after one reset and call a professional, describe the ignition pattern exactly
6 blinks persist with a clear vent, clean filter, and no scorch signsAn internal fault remains: switch, valve, board, or wiringCall a professional for testing inside the cabinet

Fixing it

  1. Record the pattern and read your door chart, about 5 minutes. Count the flashes and the pause, note whether the pattern repeats steadily, and copy the exact wording from the chart inside the blower door. If the chart is missing or unreadable, stop here and call a professional.
  2. Check thermostat, switch, breaker, and filter, about 10 minutes. Confirm the thermostat is set to Heat and above room temperature, the furnace power switch is on, the breaker is on, and the filter passes light when held up to it. Replace a clogged filter with the correct size.
  3. Clear the outside vent or flue termination, about 15 minutes. Remove snow, ice, leaves, nests, or debris from the exhaust and intake terminations, working only from the ground and only from outside. Do not insert anything into the flue.
  4. Look for scorch signs, about 5 minutes. Check the sight glass and the cabinet around the burner panel for blackened paint, soot streaks, or melted looking wire insulation. If you find any, skip the reset test entirely and call a professional with the furnace left off.
  5. Listen to one heat call, about 5 minutes. With all panels closed, listen for the inducer first, then ignition, then the blower. Note whether the inducer never starts, or starts and the furnace locks out after ignition attempts, because that timing tells the technician which fault family to test first.
  6. Reset once and observe one full cycle, about 15 minutes. With no scorch signs found, switch the furnace power off, wait at least 30 seconds, switch it back on, and watch one complete heat cycle from outside the furnace. If 6 blinks return at any point, switch the furnace off and call a professional. Do not reset a second time, never bypass a rollout switch, and never adjust a gas valve or swap wiring to keep the heat on.

Reset and clearing

Switch the furnace power switch off, wait at least 30 seconds, then switch it back on. One power reset after the external checks is the safe homeowner test for every version of this code. A 6 blink pattern that returns after one reset, with a clear vent and a clean filter, is reporting a real fault inside the furnace or its wiring. Do not keep cycling the power, do not bypass a safety switch, and do not adjust gas or wiring parts to force heat.

What it costs

Vent and filter first; switch, valve, board, or wiring last. The free external checks are the cheap outcomes. Every internal version of this code is a professional repair, and the price spread below reflects how different the Goodman, York, and American Standard faults really are.

RouteDIY costPart onlyFitted by a service
Clearing the vent termination and replacing the filter$0 to $20 for a replacement filterNo part neededNot applicable
Flame rollout switch replacement (Goodman version)Not a homeowner job, safety device at the burners$10 to $35 for the switch (estimate)$180 to $350 fitted, including diagnosis (estimate)
Modulating gas valve replacement (York version)Not a homeowner job, gas supply work$150 to $400 for the valve (estimate)$450 to $900 fitted, including diagnosis (estimate)
Polarity correction (American Standard version)Not a homeowner job, mains wiring workNo part needed in most cases$150 to $350 fitted, including diagnosis (estimate)
Control board replacement, if the board is the faultNot a homeowner job$150 to $450 for the board (estimate)$400 to $800 fitted, including diagnosis (estimate)

All prices on this page are estimates based on typical US parts and service pricing. Your model, region and the actual failed part will move the real figure.

Repair or replace note: a rollout switch, a polarity correction, or a gas valve repair is almost always worth doing, since each fitted cost is a small fraction of a replacement furnace. A control board repair on a furnace over 15 years old needs the heat exchanger checked first, because there is no sense fitting a new board to a furnace whose exchanger then fails inspection. A condemned heat exchanger almost always means a new furnace, typically $3,500 to $7,500 installed (estimate). The full pattern list is on the furnace blink codes hub, and the companion patterns are the furnace blinking 5 times guide and the furnace blinking 4 times guide.

Mistakes that make it worse

Stop and Call a Professional If

Never work on gas lines, burners, heat exchangers, or inside electrical panels. Never bypass a safety switch. If anything in this guide conflicts with your model's manual or a safety warning on the furnace, the manual and the warning win.

Frequently Asked Questions

Does 6 blinks mean the same thing on every furnace?

No. Six blinks means an open rollout switch on Goodman furnaces, a modulating gas valve failure on many York furnaces, and a polarity fault on American Standard furnaces. Other brands vary again, so the chart printed inside your blower door is the only reliable source for your model.

Can I fix a 6 blink code myself?

The homeowner part is diagnosis and external checks only: read the door chart, check the filter and the outside vent termination, listen for the inducer, and run one power reset. Rollout switches, gas valves, wiring, polarity correction, and control boards are all professional work, because they sit at the burners, the gas supply, or the mains wiring.

Is a furnace blinking 6 times dangerous?

Treat it as a stop and diagnose fault. On Goodman models it can mean flames rolled out of the burner box, which is a fire and carbon monoxide risk, and on York models it can mean a gas valve fault. If you smell gas or the carbon monoxide alarm sounds, leave the house and call your gas utility or 911 from outside, before any troubleshooting.

Related Guides

More From the Furnace Blink Codes Hub

Back to the full list: Furnace Blink Codes

Furnace Blink CodesWhat Each Pattern Means and How to Read Yours